Energy & Mining, laboratory
No service
None
None
Not Available
Provided
Ordinary Product
1 Year
other
New
Zhejiang, China
NADE
1200W*2
660mm*505mm*660mm
30KG
1 Year
Online support
Easy to Operate
AC(220±10%)V, 50Hz
1200W*2
100ml, division value 1ml
125ml,meet the requirements of GB/T 6536 and ASTM D86
(-2~300)℃ and (-2~400)℃, division value 1℃
SiC Carbide holder, bore diameter:Dia.38mm, Dia.50mm
0℃~60℃
≤30℃
≤85%
Less 3800W
Product Description
The instrument is designed and made as per standards GB/T6536 Test Method for Distillation Characteristics of Petroleum Products and ASTM D86 Standard Test Method of Distillation for Petroleum Products at Atmospheric Pressure. It is suitable to determine the distillation characteristics of gasoline, aviation gasoline, jet fuels, solvent having special boiling point, naphtha, diesel oil, distillate fuels, and other petroleum products.
This instrument is a kind of double-units instrument which the minimum temperature of the condenser pipe can reach 0℃.It is an ideal distillation tester for petroleum products under low temperature condition.
1. The test method according to standards GB/T6536 and American standard ASTM D86.
2. The instrument adopts low temperature and double units working mode. The minimum temperature can set to 0℃.It can do test for one sample or two samples at same time.The public cylinder with 0℃ to room temperature called low temperature air bath, It highly improves the work efficiency.
3. The cooling method of the condenser pipe use the refrigerating fluid and water to wrap the pipe,and use the circulating pump to realize the circulation of the mixed liquor, with digital temperature controller,fast cooling speed and high accuracy to control the temperature.
It adopts digital temperature controller, stainless-steel heater, new type refrigeration compressor and electric stirrer to constitute constant temperature bath. The temperature in the bath is uniform,can fully meet the requirements of test.
4. It adopts special heating furnace to ensure the safety of test. Heating power can be continuously adjusted to meet the requirements of test.
5. The heating furnace with the cooling fan,It can cool the temperature of the furnace quickly after the test,and reduce the awaiting time for the next test.
Model | SYD-6536B-1 | |
Power supply | AC(220±10%)V,50Hz | |
Heating power | 1200W*2 | |
Receiving cylinder | 100ml, division value 1ml | |
Distillation flask | 125ml,meet the requirements of GB/T 6536 and ASTM D86 | |
Thermometer | (-2~300)℃ and (-2~400)℃, division value 1℃ | |
Flask support board | SiC Carbide holder, bore diameter:Dia.38mm, Dia.50mm | |
Temperature controller | Range | 0℃~60℃ |
| Accuracy | ±0.5℃ |
| Display | LED |
Ambient temperature | ≤30℃ | |
Relative humidity | ≤85% | |
Cooling system | New type refrigeration compressor | |
Maximum power consumption | Less 3800W | |
Dimension | 660mm*505mm*660mm | |
Net weight | 30KG |
Notes:
1. The reagent and equipments for installing the instrument are supplied by end-users themselves.
2. The thermometer needs to be purchased by the end user. Parameter: (-2∼300)℃,(-2∼400)℃,scale division is 1℃,each 2.
3. The usage,management and saving of poisonous and harmful reagent,pls operate according to the relative principle.
4. PLS read the operation manual and industry standard before using the instrument.
Other models