You are here: Home / Products / Water quality analyzer/tester / Ion Analyzer/ ISE meter / NADE Bench Top Lab Water Hardness Meter YD200

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button

NADE Bench Top Lab Water Hardness Meter YD200

  • China

  • NADE

  • (0 ~ 10)mmol/L

Product Description

Introductions

Benchtop meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion).

Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use.

eter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage RS232 output, etc.

Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler) and mg/L (Ca). Three options of three units: ºfH(France),ºdH (Germany)and ºeH(UK) from WH-Link communication software.

Equipped with B1,B2 and B3 calibration solution.

Equipped with WH-Link communication software, connect testing data of meter to computer.

Specification

Water Hardness

Measuring range

Resolution

Accuracy

Temp. compensation

CalibrationSolution

Calibration Mode

(0 ~ 10)mmol/L;

(0 ~ 401)mg/L(Ca);(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree);(0 ~ 561)mg/L(CaO); (0 ~ 56)ºdH(German Degree);

(0 ~ 20)mmol/L(Boiler); (0 ~ 70)ºeH (England Degree).

0.01 and 0.1 water hardness units

±5% FS

(5 ~ 50)°C((automatic))

B1 Calibration Solution — 2.00×10-2 mmol/L

B2 Calibration Solution — 2.00×10-1 mmol/L

B3 Calibration Solution — 2.00 mmol/L

(B3Calibration Solution also can be used for the soaking solution of electrode)

(a)B1/B2 Calibration—using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boiler
water.

(b)Calibration—using B2 and B3 Calibration Solution,suitable forgeneral water quality.

Temperature

Measuring range

Resolution

Accuracy

0 ~ 60°C

0.1°C

±0.5°C

Other Technical Parameter

Data storage

Content Storage

Communication Connector

Power

Dimension and weight

Quality and safe certificate

128 groups

serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.

RS232

DC9V

(160×190×70)mm/750g

IISO9001:2000 and CE

working conditions

Ambient temperature

ambient humidity

(5~35)°C

≤85%RH

Standard package:

1. Model YD300 water hardness meter

1set

2.Model 601-F water hardness electrode( With two measruing heads and one screw plug )

1pc

3. Model 602 Flexible electrode holder

1pc

4.250mL water hardness calibration solution (B1, B2 and B3)

1btl/each

5.20mL test cup

4pcs

6. Test cup pedestal

1pc

7. WH-Link communication software

1 pc

8. RS-232 communication cable

1pc

9. Operation manual

1book

NADE Bench Top Lab Water Hardness Meter YD200

if you need portable type, pls turn to our model YD300

NADE Bench Top Lab Water Hardness Meter YD200

Contact information

NADE Bench Top Lab Water Hardness Meter YD200

Packaging & Shipping

NADE Bench Top Lab Water Hardness Meter YD200

Company Information

Previous: 
Next: 