GENERAL FEATURES
● Color High contrast LCD touchscreen, 7.0 inches.
● Intelligent operation system provides features including user management, calibration management, method management, data management and etc.
● Multi-reading feature allows auto-read, timed-read and continuous-read.
● Automatic/Manual temperature compensation ensures accurate results.
● Data Storage 1000 sets for each parameter (GLP-compliant).
● Data analysis feature helps user review, compare and recalculate results.
● Support for USB or RS-232 communication.
● Reset feature automatically resumes all settings back to factory default options.
● IP54 waterproof.
Ion
● 1-6 points calibration
● Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.
● Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
● Over 10 methods are built-in, including F- , Cl- , Br- , I- , NO3 - , BF4 - , NH4 + , K+ , Na+ , Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
pH
● 1-6 points calibration with Standard Recognition.
● Selectable pH buffer groups, including DIN, NIST, USA, MERK, JIS, GB.
● Support for pH standard group customization.
● Automatic electrode diagnosis with pH slope and offset display.
Specification
Model | I500T | |
Parameters | pH/ISE/Temp.(mV/ORP/pX) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ± 0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ± 0. 1 mV or ± 0.03% of reading whichever is greater | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ± 0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 1E-9 to 9.999E9 |
Units | mol/L, mmol/L, g/L, mg/L, μ g/L, ppm | |
Resolution | Up to 4 significant digits | |
Accuracy | ± 0.3% | |
Calibration Points | Up to 6 | |
Temperature | Range | - 10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Accuracy | ± 0. 1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
Temp. Probe | 4-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC |
RS 232 | printer, scanner, auto-sampler | |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Power | AC Adapter, 100-240V AC input, DC24V output |
Dimensions | 220 × 195 × 68 mm | |
Weight | 950g (2.09 lb) |