Availability: | |
---|---|
M300F
AC Adapter, 100-240V AC input, DC9V output
1
1 year
China
Product Description
GENERAL FEATURES
● High resolution LCD display, 5.7 inches.
● Multi-reading feature allows auto-read, timed-read and continuous-read.
● Automatic/Manual temperature compensation ensures accurate results.
● Auto-hold feature senses and locks the measurement endpoint.
● Data Storage 500 sets (GLP-compliant).
● Support for USB or RS-232 communication.
● Reset feature automatically resumes all settings back to factory default options.
● IP54 waterproof.
Automatic identification standard solution
Fast calibration and more accurate measurement
Multiple external devices available PC, printer
Ion
● 1-6 points calibration
● Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.
● Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode
and GRAN mode.
● Over 10 methods are built-in, including F- , Cl- , Br- , I- , NO3 - , BF4 - , NH4 + , K+ , Na+ , Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
pH
● 1-5 points calibration with Standard Recognition.
● Selectable pH buffer groups, including NIST, DIN, GB.
● Automatic electrode diagnosis with pH slope and offset display.
Conductivity
● 1-3 points calibration with Standard Recognition.
● Settable parameters, including cell constant, temperature compensation coefficient and TDS factor.
● Temperature compensation type (none, linear, pure water).
DO
● Support for air-saturated water or zero oxygen calibration.
● Auto barometric pressure compensation
● Manual Salinity Factor Correction
● Selectable pressure unit, including kPa, mbar, Torr, Atm.
Specification
Model | M300F | |
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.00 to 20.00pH |
Resolution | 0.1, 0.01 pH | |
Accuracy | ± 0.01 pH | |
Calibration Points | Up to 5 | |
Standard Customization | Yes | |
Standard Recognition | NIST, GB and DIN buffers | |
Slope Limit | Yes | |
mV | Range | -2000.0 to 2000.0 mV |
Resolution | 0.1 mV | |
Accuracy | ± 0.3 mV or ± 0. 1% | |
pX | Range | -2.00 to 20.00 |
Resolution | 0.1, 0.01 pX | |
Accuracy | ± 0.01 pX | |
Calibration Points | Up to 5 | |
ISE | Range | 1E-9 to 9.999E9 |
Unit | mol/L, mmol/L, g/L, mg/L, μ g/L, ppm | |
Resolution | Up to 4 significant digits | |
Accuracy | ± 0.5% | |
Calibration Points | Up to 5 | |
Conductivity | Range | 0.000 μ S/cm to 1000 mS/cm |
Resolution | 0.001 μ S/cm minimum, various with range selection | |
Accuracy | ± 1.0% FS | |
Reference Temperature | 20, 25 ºC | |
Calibration Points | Up to 3 | |
Standard Recognition | 84 μ S/cm, 1413 μ S/cm, 12.88mS/cm | |
Resistivity | Range | 5.00 Ω ·cm~20.00 M Ω ·cm |
Resolution | 0.01 Ω ·cm minimum | |
Accuracy | ± 1.0% FS | |
TDS | Range | 0.00mg/L~300g/L |
Resolution | 0.01mg/L minimum, various with range selection | |
Accuracy | ± 1.0% FS | |
Salinity | Range | (0.00~8.00)% |
Resolution | 0.01% | |
Accuracy | ± 0.2% | |
Dissolved Oxygen Con- centration | Range | 0.00 to 20.00 mg/L |
Resolution | 0.01mg/L | |
Accuracy | ± 0. 1mg/L | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
Saturation | Range | (0.0 to 200.0)% |
Resolution | 0.1% | |
Accuracy | ± 2.0% | |
Temperature | Range | -5 to 110 ºC, 23 to 230 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Accuracy | ± 0.2 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 500 results each |
GLP Features | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 4-pin aviation connector | |
Conductivity with Temp. Probe | 5-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC |
RS 232 | printer | |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Power | AC Adapter, 100-240V AC input, DC9V output |
Dimensions | 242 × 195 × 68 mm | |
Weight | 900g (1.98 lb) |
Configuration
E-301-QC 3 in 1 pH Composite Electrode
DJS-1VTC Conductivity electrode
DO-958-Q Dissolved oxygen electrode
NIST pH Standard Solution (4.01, 7.00, 10.01) one bottle each (50ml/bottle)
1413μS/cm Conductivity Standards one bottle (50ml/bottle)
REX-5 Multifunction Electrode Stand
DZS-706F
content is empty!