Availability: | |
---|---|
UV-6100S
AC 110/220V 50/60Hz
1
1 year
China
Product Description
UV-6000 Series is an advanced double beam design consisting of 3 models.
UV6100 with 1.8nm fixed bandwidth.
UV6300 with 1.0 fixed bandwidth.
UV6100S with variable bandwidth:0.5/1/2/5nm.
Other specifications of the six models are almost the same except bandwidth.
The two detectors measure sample and reference respectively and simultaneously for optimizing measurement accuracy.
They provide excellent performance for measurements in the range of 190 to 1100nm.
They are suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analysis, kinetics, wavelength scan, multiple components and DNA/Protein, PC Windows application software make these instruments versatile.
All instruments provide excellent performance for measurements.
Features
Fixed or variable slits(bandwidths)
For Stand-alone models, all software methods are included as built-in standard; this eliminates the need of software.
Online software upgrading via internet helps to keep it updated.
Data Download-to-PC software expands the data storage to unlimited.
The stand-alone model has 5 inch screen and the PC model has UV/Vis Analyst software.
Specification
Model | UV-6100 UV6100PC | UV-6300 UV-6300PC | UV-6100S UV-6100PCS | |
Wavelength Range | 190-1100nm | |||
Spectral Bandwidth | 1.8nm | 1.0nm | 0.5,1,2,4nm | |
Optical System | Double Beam , Grating 1200 lines/mm | |||
Wavelength Accuracy | ±0.3nm | |||
Wavelength Repeatability | 0.2nm | |||
Scan Speed | Hi ,MED. ,LOW. ,MAX. 3000nm/min | |||
Photometric Accuracy | ≤±0.5%T or ±0.005A@1A | |||
Photometric Range | 0-200%T , -0.3 - 3A . | |||
Stray Light | 0.05%T@220 ,340nm | |||
Stability | ±0.001A/h @500nm | |||
Display | 5 inches LCD(320*240 dots) | |||
Baseline Flatness | ±0.001A | |||
Standard Cell Holder | Standard 10mm single cell holder (2 pcs) | |||
Sample Compartment | Standard 10mm pathlength cuvette | |||
Light Source | Tungsten & Deuterium lamp(pre-aligned) | |||
Output | USB Port & Parallel Port(printer) | |||
Power Requirement | AC 110/220V 50/60Hz | |||
Dimensions(W*D*H) | 600*450*200mm | |||
Weight | 22kg |
UV6000 series are all with PC software.
Introduction for UV-6000 Series Local Control Software:
All methods are included as built-in standard; this eliminates the need of software. Online software update via internet.
The local control software includes functions such as: Photometry, Quantitative, Wavelength Scan, Kinetics, DNA/Protein, Multi-wavelength and System Utilities.
Standard Curve
Up to 10 standard solutions may be used to establish calibration equation curve. There is a choice of four methods for fitting a curve through the calibration points: Linear fit, Linear fit through zero, square fit and cubic fit.
Wavelength Scan
The Wavelength Scan intervals are 0.1, 0.2, 0.5, 1, 2, 5nm, and High, Medium and Low scan speeds are available. Scan speeds vary from 100 to 1000 nm/min. Wavelengths are scanned from high to low so that the instrument stand by at high wavelength. This minimizes the degradation of UV sensitive samples. Precise control of filter and lamp changes means that their effects are not seen on the final scan. Post-run manipulation includes re-scaling axes, curve tracking and peak picking.
Kinetics
This mode may be used for scanning time course or reacting rate calculations. Abs. vs. time graphs is displayed on the screen in real time.
Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5, 1, 2,5, 10, 30, seconds and 1 min.
Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.
Multi-Wavelength
Up to 10 wavelengths may be entered, allowing the measurement of multiple wavelengths on a series of Samples
DNA/Protein Test
Concentration and DNA purity are calculated by
Absorbance ratios 260nm/280nm or 260nm/230nm with optional subtracted absorbance at 320nm
DNA Concentration=62.9*A260-36.0*A280
Or 49.1*A260-3.48*A230
Protein Concentration=1552*A260-757.3*A280
Or 183*A260-75.8*A230
Other wavelengths and factors may be entered.
UV/Vis Analyst for UV-3000 &UV-6000 Series
The windows based PC application software UV/Vis Analyst takes the best features of the stand-alone version plus more powerful data processing, expanded data collecting, and storage capability. It comes standard with PC models and is optional to stand-alone models.
The PC application software offers:
Photometric Mode
Quantitative test(standard curve)
Wavelength Scan
Kinetics
DNA/Protein
Multi-Wavelength
System Utility
content is empty!