Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20

  • Zhejiang, China

  • Nade

  • 1~20

  • 20~3000ul

  • >95%

  • 20

  • Tubes with double sample tubes (Special design)

  • Lysis, Sample binding, Washing and elution

  • 7 inch color touch screen

  • 100 copy sample positive rate >95%

  • For cell lysis: Ambient temperature ~90℃

  • Nucleic Acid Purification System

Product Description

Nade Nucleic Acid Purification System AUTO-PURE20
Product Description

Auto-Pure20 / Auto-Pure32 is a bench top device for DNA and RNA purification by using magnetic separation technology from different starting materials, such as blood, cultured cells or bacteria, tissues, cell-free body fluids and plant samples. The device is capable of using magnetic rods to transfer particles through the various purification phases of binding, mixing, washing and elution, offering a solution with minimized hands-on time. The DNA and RNA purification is of high quality and high molecular weight.

FEATURES
1. It is easy to use with 7 inch touch screen
2. Very simple operation (easy to install, operate, maintain) without computer
3. Very fast extraction protocol, 15~40 minutes / cycle depending on sample type and method
4. Universal built-in program for easy using
5. High purity and excellent yield of nucleic acid
6. UV lamp to avoid cross contamination
7. 3 shortcut key to make for easy running, stopping the magnetic beads program
8. Open system can optimize purification proposal according to various magnetic beads kits
9. Drawer design to prevent possible injuries
10. With special plastic consumables to avoid cross contamination
11. Improves workflow, and allows staff to perform other value-added tasks
12. Ensures impurities are removed; improved sample quality leads to better downstream analyses
13. Capable of extracting 1~20 samples or 1~32samples per run
14. Alarm for indicating the completion of purification
15. Pause function for emergent stop
TECHNICAL DATES

Type

Auto-Pure20A

Auto-Pure20B

Auto-Pure32A(click model for more details)

Throughput

1~20

1~32

Process volume

50~3000ul

50~5000ul

50~1000ul

Collection efficiency

>95%

>95%

>95%

Magnetic rod number

20

20

32

Purification accuracy

100 copy sample positive rate>95%

Stability

CV<5%

Plate types

3ml tube strip

5ml tube strip

96 Deepwell plate

Healting for lysis tube

Ambient temperature~120°C

Heating for elution tube

Ambient temperature~120°C

Operation

7 inch color touch screen

Extraction steps

Lysis, Sample binding, Washing and elution

Storage Capacity

more than 100 programs

Protocol Management

Create, edit, delete, protocol mode

Pollution Control

UV light

Lighting

Yes

Extension interface

4 standard USB port, built-in SD card

Exhaust

Fan

Power Supply

450W

Dimensions

400×520×450mm

Weight

28Kg

28Kg

25Kg

Packaging & Shipping

Our Packaging Details:

Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20

Our Shipping

Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20

Our Services

Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20

Company Information

Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20

Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20

Hot Selling Products

Hot Selling Products..........

Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20 Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20 Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20
Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20 Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20 Nade Nucleic Acid Extractor/Nucleic Acid Purification System AUTO-PURE20

FAQ

Q: How long is the delivery time?
A: 7-15 working days after we received your payment or order confirmed.


Q: What is the warranty for the equipment?
A: One year. We can provide you lifelong technical support.


Q: What is the payment terms?
A: T/T, L/C, Western Union, etc.

Q: What after-sales service can be provided by Nade ?
A: The after-sales service of Nade is divided into two parts: technical support and maintenance.


Q: What about the technical support and maintenence?
A: Sometimes users will get some problems when they operate the instruments which are unfamiliar or first time use, users can send us emails or call us about detailed information. We will provide users solution or operation video.For so many years’ experience, our instruments works well during warranty period. If there any parts are broken during warranty period, we would like to provide spare parts for free.

Please send your request details to us by clicking "send" at the bottom!

Previous: 
Next: 

googleTranslate