| Availability: | |
|---|---|
MP551
NADE
DC9V
1
1 year
China
Product Description
The MP551 is a laboratory-grade, high-precision, multi-parameter benchtop electrochemical instrument. With this instrument, you can cover all aspects of water quality testing, including more than 10 electrochemical parameters such as pH, ion concentration, conductivity, and dissolved oxygen.
It boasts an extremely wide range of applications, suitable for industries like petroleum, chemicals, pharmaceuticals, power plants, and environmental protection. It has also long enjoyed a strong reputation in the fields of education and scientific research.
Leveraging its advanced digital processing technology, the instrument consistently delivers fast, accurate, stable, and higher-precision measurement results, earning it high trust from users.
Specification
Model | MP551 | |
pH | Measuring range | (-2.000 ~ 19.999) pH |
Resolution | 0.1/0.01/0.001 pH | |
Accuracy | Meter:±0.002 pH, connect meter with electrode:±0.01pH | |
Stability | ±0.002 pH/3h | |
Temp. Compensation Range | (0 ~100)°C (Automatic or Manual) | |
| Measuring range | -1999.9mV ~0 ~1999.9mV |
Resolution | 0.1mV | |
Accuracy | ±0.03% FS | |
Ion Concentration | Measuring range | 0.00 ~ 14.00 pX |
Display unit | pX, mol/L, mg/L, ppm | |
Accuracy | Meter:±0.5% of reading (for monovalent ions), ±1.0% of reading (for divalent ions) | |
Temp. compensation range | (0 to 60) ℃ ( automatic or manual ) | |
Preset ion mode | Na+, F-, Cl-, Br-, I-, Cu2+, Ca2+, K+, NH4+, NO3 | |
Conductivity | Measuring range | Conductivity: (0.00~20.00)μS/cm (20.0~200.0)μS/cm |
Resolution | 0.01/0.1/1μS/cm 0.01/0.1/1 mS/cm | |
Accuracy | Meter:±0.5% FS,connect meter with electrode:±0.80% FS | |
Temp. compensation range | (0 ~ 50)℃(automatic ) | |
Electrode constant | 0.1 / 0.5 / 1 / 5 / 10 / 50 / 100 cm-1 | |
Reference temperature | 25℃, 20℃ and 18℃ | |
Dissolved Oxygen | Measuring range | (0 ~ 20.00)mg/L(ppm) (0 ~ 200.0)% |
Resolution | 0.1/0.01 mg/L(ppm) 1/0.1 % | |
Accuracy | Meter: ±0.10 mg/L,connect meter with electrode: ±0.40 mg/L | |
Response time | ≤30 s(25℃, 90% response) | |
Residual current | ≤0.1 mg/L | |
Temp. compensation range | (0 ~ 45)℃(automatic) | |
Salinity compensation range | (0 ~ 45)ppt(automatic) | |
Air pressure compensation | (80 ~ 105)kPa(automatic) | |
Automatic calibration | Air saturated by water; water saturated by air | |
Electrode type | Polarogram type | |
| Range | -10°C ~110°C |
Resolution | 0.1°C | |
Accuracy | 5~ 60℃range:±0.4℃ other range:±0.8℃ | |
Other Technical Parameters | Data storage | 300 groups |
Storage content | serial number, date, time, measurement value, temperature value, ATC or MTC state | |
Communication connector | RS232 | |
Power | DC9V/300mA | |
Size and weight | 160 × 190 × 70mm/880g | |
Quality and safety certification | ISO9001, CE and CMC | |
| Environment temperature | 5 ~ 35 ℃(0.01grade) 15 ~ 30 ℃(0.001grade) |
Environmental humidity | ≤75% | |
IP rating | IP54 Dustproof and waterproof | |
content is empty!