FPOSM-V3.0 Automatic Freezing Point Osmometer

Measurement range: 0~3000 mOsmol
Sample amount: 100μl
Testing duration: ≤3min
Model:
Availability:
  • FPOSM-V3.0

  • NADE

Product Description

The freezing point osmometer FPOSM-V3.0 produced by our company with independent research and development is in accordance with Raoul freezing point theory, based on the solution freezing point declined value proportional to the solution molar concentration, using high sensitivity of temperature- sensing element, to measure the freezing point of different solutions, so as to derive the osmotic pressure molar concentration.



Features

※It has the functions of electronic signature and user classification management, to satisfy CFR PART21 store data query according to time which can store 3 years of testing data. 

※ It can carry on single-point or multi-point (31-point) linear calibration, to ensure that the instrument has the detection accuracy of each range interval in stability. 

※Instrument adopts the screw linear guide motor design, so that the operation just on a touch screen can complete the whole test process. 

※ Temperature probe  adopts double refrigeration system, with a short pre- cooling time, fast detection speed,to facilitate continuous detection. 

※ It can simultaneously display the osmotic pressure molar concentration value, the freezing point value and the molar concentration ratio. 

※ The cooling system adopts the athermal transfer fluid design, to exempt from frequent maintenance.

 ※ Built-in "Chinese pharmacopoeia" hundreds of injectable drug name can facilitate the preset information of test sample.

Applications

This theory has been widely used for the test and research of osmotic pressure molar concentration in the fields such as pharmaceuticals,pharmaceutical analysis, biological and food therapy.

Specifications

Measurement range

0~3000 mOsmol

Sample amount

100μl

Testing duration

≤3min

Pre-cooling time

≤3min

Measurement

error

≤1%

Repeatability

≤1%

Linearity

≤1%

Environment temperature

0~30℃ Recommended for 15~25℃

Environment temperature

≤60%

Power supply

220V~ 50Hz 150VA

Dimensions

340mm*300mm*400mm

Weight

17kg