Availability: | |
---|---|
DM1424
NADE
DM1424
100~120V /200~240V,50/60HZ
1
1 year
China
Product Description
with AC24 rotor kit
Hematocrit centrifuges are used for determination of erythrocyte fractions in blood as well as micro solution separations. It provides hematocrit values (HCT) for testing in biochemistry, immunity, genetics, blood separation and for general clinical tests for diagnostic purposes and also for dope tests. They have special applications for the photometric determination of bilirubin content in neonate blood samples. They are suitable for extraction of DNA and RNA. Veterinary clinics and Vitamins testing for Infants.
Features
1.Speed range of 200-12000 rpm Precise and independent control of speed and time
Advantages
-Clinical centrifuges have passed the explosion-proof test and marked with CE, cTUVus and FCC. MCA test according to IEC/EN61010-2-20 including explosion-proof and bio-safe tests.
-Passed EN61010-2-101:2002 particular requirements for in vitro diagnostic (IVD) medical equipment
-High strength plastic rotor and excellent balance technology to guarantee a quiet and stable operation
-Dual protection casing provides safe and reliable running
-Brushless motor drive quickly and effortlessly accelerates the rotor to set speed
Precise control
-CPU controls all operating parameters including speed and time
-High accuracy of speed, excellent performance
-Operation can be timed from 30 seconds to 99 minutes or continuous running
-Timer commences once the set speed is reached, so the separation time is more accurate
-Gentle braking at low speeds with efficient separation
Ergonomic design
-User-friendly large LCD display show all information
-RPM or G-force can be set and displayed
-Parameters can be modified after the set speed is reached
-Quick spins are possible by pressing and holding PULSE key. The centrifuge speed can be accelerated and held at the target speed.
-Automatic release the lid when operation has stopped to save processing time
-Easy-to-read processing display and sound alert
Specifications
Specifications | DM1424 | DM1224 |
Speed Range | 200-12000rpm,increment:10rpm | 500-12000rpm, increment:100rpm |
Max. RCF | 13680 x g | 13680 x g |
Speed Accuracy | ±20 | ±100 |
Run Time | 30sec-99min/Continuous | 10sec-99min/Continuous |
Motor | Brushless DC motor | Brushless DC motor |
Display | LCD | LCD |
Safety Devices | Door interlock, Overspeed detector; Automatic internal diagnosis, Automatic rotor identification | Door interlock |
Acceleration/Braking time | 30s↑30s↓ | 40s↑40s↓ |
Power Requirements | Single-phase, 200V-240V,50Hz/60Hz, 5A; 100V-120V,50Hz/60Hz, 5A 160W | Single-phase, 200V-240V,50Hz/60Hz, 5A; 380W |
Dimension[WxDxH] | 280x364x274mm | 280x364x213mm |
Weight | 10.5kg | 8.5kg |
Advanced features | Speed/RCF switch; Short-time run function; sound-alert function | Speed/RCF switch; Short-time run function; sound-alert function |
Accessories
Available rotors | ||
AC24 | Cat.No.19400047 | |
DM1424 & DM1224 Max. speed:12000rpm Max.RCF:13680 x g Rotor capacity: capillary tubes x24 Rotor material: High strength aluminum |